ZHOU Yong, JIANG Zeying, SU Baofeng, ZHOU Jianfeng, WANG Qian, WANG Anting, LIU Jingxian, XUE Yan, FENG Huiyi, WU Xiaoliang, XIAO Mingxing, TAN Wenyong. Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment[J]. Cancer Research on Prevention and Treatment, 2023, 50(11): 1097-1102. DOI: 10.3971/j.issn.1000-8578.2023.23.0288
Citation: ZHOU Yong, JIANG Zeying, SU Baofeng, ZHOU Jianfeng, WANG Qian, WANG Anting, LIU Jingxian, XUE Yan, FENG Huiyi, WU Xiaoliang, XIAO Mingxing, TAN Wenyong. Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment[J]. Cancer Research on Prevention and Treatment, 2023, 50(11): 1097-1102. DOI: 10.3971/j.issn.1000-8578.2023.23.0288

Application of Linear Accelerator on Boarding Kilovolt Fan Beam CT and Megavolt Cone Beam CT System on Set-up Errors During Radiation Treatment

  • Objective To quantify the setup errors for the different anatomical sites of patients who received intensity-modulated radiotherapy (IMRT) with linear accelerator on-board kilovolt fan beam CT(kV-FBCT) as non-isocenter IGRT and megavolt cone beam CT (MV-CBCT) as isocenter IGRT.
    Methods A retrospective analysis was performedon 70 patients who underwent radiotherapy, kV-FBCT, and/or MV-CBCT scans after each routine setup prior to IMRT. The average displacement (M), systematic error (Σ), and random error (б) at different treatment sites in the left-right, anterior-posterior, and cranial-caudal directions were calculated according to the individual displacements. The formula 2.5Σ+0.7б was used to estimate the PTV margin in respective direction. For each single patient, the root mean square in three directions was used as 3D displacement.
    Results A total of 1130 displacements were recorded in the 70 patients. The PTV margin was estimated to be 1.9-3.1 mm in head and neck cancer, 2.8-5.1 mm in thoracic cancer, 4.6-5.1 mm in breast cancer, 3.0-5.5 mm in upper abdominal cancer, and 3.5-6.8 mm in pelvic tumor. For the 3D mean displacements, the head and neck, thoracic, breast, upper abdominal, and pelvic cancer were 2.4±1.0, 4.0±1.6, 4.1±2.0, 4.6±2.1, and 4.6±2.1 mm, respectively. The average 3D displacement obtained by kV-FBCT and MV-CBCT were 4.1 and 3.4 mm, respectively (P=0.212).
    Conclusion The quantitative setup-error data can be obtained using linear accelerator on-board FBCT, and the non-isocenter IGRT induced set-up error cannot be negligible.